Daikin Air Conditioning Controller Instructions
. ARC433 Series Si10-416B ARC433B46, B47 ECONO ON/OFF TEMP POWERFUL MODE SWING QUIET MOLD PROOF SENSOR CANCEL TIMER Remote Controllers. Si10-416B ARC433 Series 1. Signal transmitter 2.
Display It displays the current settings. (In this illustration, each section is shown with all its displays ON for the purpose of explanation.) 3. ECONO button 4.
POWERFUL button 5. TEMPERATURE adjustment buttons 6. Si10-416B ARC433 Series 5. ARC433 Series 5.1 Preparation Before Operation To set the batteries 1. Slide the front cover to take it off.
Set two dry batteries (AAA). Set the front cover as before. Position + and – correctly! ATTENTION About batteries. ARC433 Series Si10-416B To operate the remote controller. To use the remote controller, aim the transmitter at the indoor unit. If there is anything to block signals between the unit and the remote controller, such as a curtain, the unit will not operate.
View and Download Daikin Remote Controller BRC1C61 operation manual online. Remote Controller BRC1C61 Air Conditioner pdf manual download.
Daikin Ac Remote Controller Manual may result due to contact with the air conditioner's high-speed fan blades. • Do not attempt to This switch can be used when the. View and Download Daikin BRC1D61 operating manual online. Remote controller. BRC1D61 Air Conditioner pdf manual download.
Si10-416B ARC433 Series ATTENTION About remote controller. Never expose the remote controller to direct sunlight. Dust on the signal transmitter or receiver will reduce the sensitivity. Wipe off dust with soft cloth. Signal communication may be disabled if an electronic- starter-type fluorescent lamp (such as inverter-type lamps) is in the room. ARC433 Series Si10-416B To set the clock 1. Press “CLOCK button”.
Is displayed. Press “TIMER setting button” to set the clock to the present time. Holding down “ ” or “ ” button rapidly increases or decreases the time display.
Si10-416B ARC433 Series 5.2 AUTO. DRY. COOL.
HEAT. FAN Operation The air conditioner operates with the operation mode of your choice. From the next time on, the air conditioner will operate with the same operation mode. To start operation 1. ARC433 Series Si10-416B To change the temperature setting 4. Press “TEMPERATURE adjustment button”. DRY or FAN mode AUTO or COOL or HEAT mode Press “ ” to raise the temperature and press “ ” The temperature setting is to lower the temperature.
Not variable. Si10-416B ARC433 Series NOTE Note on HEAT operation. Since this air conditioner heats the room by taking heat from outdoor air to indoors, the heating capacity becomes smaller in lower outdoor temperatures. If the heating effect is insufficient, it is recommended to use another heating appliance in combination with the air conditioner.
ARC433 Series Si10-416B 5.3 Adjusting the Airflow Direction You can adjust the airflow direction to increase your comfort. To adjust the horizontal blade (flap) 1. Press “SWING button ”. “ ” is displayed on the LCD and the flaps will begin to swing.
Si10-416B ARC433 Series To 3-D Airflow Press the “SWING button ” and the “SWING button ”: the “ ” and “ ” display will light up and the flap and louvers will move in turn. To cancel 3-D Airflow Press either the “SWING button ”. ARC433 Series Si10-416B 5.4 COMFORT AIRFLOW Operation To start COMFORT AIRFLOW operation 1. Press “COMFORT AIRFLOW button”.
The flap position will change, preventing air from blowing directly on the occupants of the room. “ ” is displayed on the LCD. Si10-416B ARC433 Series 5.5 POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operation mode. You can get the maximum capacity. To start POWERFUL operation 1.
Press “POWERFUL button”. POWERFUL operation ends in 20 minutes. Then the system automatically operates again with the settings which were used before POWERFUL operation. ARC433 Series Si10-416B 5.6 OUTDOOR UNIT QUIET (SILENT) Operation OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor unit by changing the frequency and fan speed on the outdoor unit. This function is convenient during night.
To start OUTDOOR UNIT QUIET operation 1. Si10-416B ARC433 Series 5.7 HOME LEAVE Operation HOME LEAVE operation is a function which allows you to record your preferred temperature and airflow rate settings. To start HOME LEAVE operation 1. Press “HOME LEAVE button”. “ ” is displayed on the LCD. ARC433 Series Si10-416B What’s the HOME LEAVE operation? Is there a set temperature and airflow rate which is most comfortable, a set temperature and airflow rate which you use the most?
HOME LEAVE operation is a function that allows you to record your favorite set temperature and airflow rate. Si10-416B ARC433 Series. Before bed. Set the unit to HOME LEAVE The unit will maintain the Operation before leaving the living temperature in the room at a room when going to bed. Comfortable level while you sleep. When you enter the living room in the morning, the temperature will be just right.
ARC433 Series Si10-416B 5.8 ECONO Operation ECONO operation is a function which enables efficient operation by lowering the maximum power consumption value. To start ECONO operation 1.
Press “ECONO button”. “ ” is displayed on the LCD. To cancel ECONO operation 2. Si10-416B ARC433 Series 5.9 MOLD PROOF Operation MOLD PROOF operation is a function which reduces the spread of mold by using Fan mode to lower the humidity inside the indoor unit.
To set MOLD PROOF operation 1. Press and hold the MOLD PROOF button for two seconds. ARC433 Series Si10-416B 5.10INTELLIGENT EYE Operation “INTELLIGENT EYE” is the infrared sensor which detects the human movement. To start INTELLIGENT EYE operation 1. Press “SENSOR button”. “ ” is displayed on the LCD. To cancel the INTELLIGENT EYE operation 2.
Si10-416B ARC433 Series “INTELLIGENT EYE” is useful for Energy Saving. Energy saving operation. Change the temperature –2˚C in heating / +2˚C in cooling / +1˚C in dry mode from set temperature.
Decrease the airflow rate slightly in fan operation. (In FAN mode only) Notes on “INTELLIGENT EYE”. ARC433 Series Si10-416B 5.11TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use OFF TIMER and ON TIMER in combination.
To use OFF TIMER operation. Si10-416B ARC433 Series NOTE. When TIMER is set, the present time is not displayed. Once you set ON, OFF TIMER, the time setting is kept in the memory. (The memory is canceled when remote controller batteries are replaced.). ARC433 Series Si10-416B To use ON TIMER operation.
Check that the clock is correct. If not, set the clock to the present time. Press “ON TIMER button”. Is displayed. Press “TIMER Setting button” until the time setting reaches the point you like. Si10-416B ARC433 Series 5.12Note for Multi System 〈〈 〉〉 What is a “Multi System”?
This system has one outdoor unit connected to multiple indoor units. Selecting the Operation Mode 1. With the Priority Room Setting present but inactive or not present. When more than one indoor unit is operating, priority is given to the first unit that was turned on. ARC433 Series Si10-416B 2. With the Priority Room Setting active.
See “Priority Room Setting” NIGHT QUIET Mode (Available only for cooling operation) NIGHT QUIET Mode requires initial programming during installation. Please consult your retailer or dealer for assistance. NIGHT QUIET Mode reduces the operation noise of the outdoor unit during the night time hours to prevent annoyance to neighbors. Si10-416B ARC433 Series Priority Room Setting The Priority Room Setting requires initial programming during installation. Please consult your retailer or dealer for assistance. The room designated as the Priority Room takes priority in the following situations; 1. Operation Mode Priority.
Daikin Air Conditioning Manual
As the operation mode of the Priority Room takes precedence, the user can select a different operation mode from other rooms.
. Using Remote Controller BRC1C61 Dear Owner, Thank you for installing a DAIKIN Fully Ducted Air Conditioning System. We believe that you have purchased the best air conditioning system available. Before operating the air conditioner please read this operating manual carefully. It will advise you on how to operate the unit correctly, understand the air conditioner’s advanced. Only use a qualified installer for installation of the air Be sure to use separately sold component parts designated conditioner. Incomplete installation performed by yourself Incorrect installation performed may result in a water may result in a water leakage, electric shock or fire.
This operation manual is for the following systems with standard control. Before initiating operation, contact your Daikin dealer for the operation that corresponds to your system. If your installation has a customized control system (eg zone control) ask your Daikin dealer for the operation that corresponds to your system. REMOTE CONTROLLER TEST AVAILABLE TEST Fig. 1 IMPORTANT NOTES ABOUT INSTALLATION Ensure the outdoor unit is installed in:- a. A place that can sufficiently withstand the weight of the air conditioner with less running noises and vibrations.
A place where the hot air stream discharged from the air outlet of the outdoor unit and the running noises do not bother your neighbours. FUNCTIONS OF THE REMOTE CONTROLLER All controls except for the ON / OFF BUTTON are located behind a swing door on the bottom half of the remote controller. To access these controls simply open the door by gently pulling down on the finger grip located on the top right hand edge of the door.
GENERAL OPERATION 4. Select the desired fan speed (if required) by pressing the FAN SPEED SELECTOR BUTTON (19). COOLING (see Fig.
Daikin Air Conditioning Ductless
2) Notes: As the air conditioner incorporates a hot start system, the indoor 1. Press the MODE SELECTION BUTTON (20) (if required) fan will run at an extra low (or low) speed irrespective of the until the COOL MODE INDICATOR ( ) is displayed. Adjust the desired room temperature (if required) by momentarily pressing on the up or down arrow TEMPERATURE SET BUTTON's (17) until the desired temperature is displayed. Each press of the button will increase or decrease the desired temperature by 1 degree. The desired temperature may be set in the range of 16 - 32 degrees. HOT START SYSTEM (Heat Pump Models only) To prevent a cold draft when the air conditioner turns on in the heating mode the indoor unit incorporates a computer controller hot start system. The indoor unit microprocessor monitors the temperature of the indoor heat exchanger and operates the indoor fan at a speed lower than the TEST AVAILABLE.
Turn off the main power supply switch when not 15.11 Not Malfunction of the Air using for long periods of time. Electricity is Condtioner consumed as long as the switch is on. Turn off the The following symptoms do not indicate that the air main power supply switch in order to save energy. TEST Dust may blow out from the unit after starting operation from long resting time.
Daikin Central Controller
Measure: Notify your Daikin dealer and inform Dust that has settled in the unit is blown out. Him/her of the display. THE AIR CONDTIONER GIVES OFF ODOURS. Turn off the main power supply switch for saving energy.
NOTE The display on the remote controller will vanish when The air filter(s) and the suction grille(s) are supplied by the main power switch is turned off. Ask your DAIKIN dealer how to clean them. DAIKIN A A USTRALIA P P TY. L L IMITED 77-83 Alfred Road, Chipping Norton, NSW 2170 Australia Customer Service: 1300 787 266 www.daikin.com.au DAIKIN I I NDUSTRIES L L TD. Head office: Umeda Centre Building, 4-12 Nakazaki-Nishi 2 chome.